Procedure - Solid Samples
Determine the instrument blank.
Repeat steps 2b through 2g a minimum of three times.
Set the blank following the procedure outlined in the operator's instruction manual.
Instrument calibration/drift correction.
Login a minimum of 3 Standard replicates.
Weigh approximately *** grams of a calibration/drift standard, enter the mass and standard identification into appropriate replicate fields.
Note: LECO Reference Materia***o not require preparation.See preparation statement on the reference material certificate.
OHN836系列仪器采用惰性熔融法。上海分析仪多少钱
User-Friendly Brand Software Cornerstone
LECO's exclusive brand software enables the user to have complete access to analysis Cornerstone control, method settings, diagnostics, reporting, and more in a highly organized and immersive environment. Designed through a collaboration of customer feedback and innovative engineering,Cornerstone allows the user to conduct all of their day-to-day operations within a single Analysis screen designed for speed and ease-of-use. Our innovative grouping of sample data into sets and replicates simplifies the data output and automatically calculates relevant statistics, alleviating the need for additional data processing.
北京LECO分析仪厂家直销高性能的红外检测器配置***恒温绝热技术,消除了外界环境温度的干扰。
Procedure – Powder/Chip Samples
Instrument calibration/drift correction.
Add approximately 0.05 g of *** Graphite Powder to a***Graphite Crucible.
Firmly place the crucible on the lower electrode tip or appropriate autoloader position.
Press the Analyze button on the instrument screen,the lower electrode will close and the analysis sequence will start and end automatically.
Repeat steps 3b through 3i a minimum of three times for each calibration/drift standard used.
Procedure - Solid Samples
Prepare the instrument as outlined in the operator's instruction manual.
Determine the instrument blank.
Login a minimum of 3 Blank replicates.
Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open. Place a 502-344 Nickel Basket into the loading head.
Note: samples using automation should be placed in the appropriate autoloader position before starting the
analysis sequence. Once the sequence has started, the automatic analysis will start and end automatically.
LECO—Your source for total analytical solutions
CS CS 844 and 744 Series: Carbon/Sulfur by Combustion
Carbon and sulfur determination by combustion infrared detection
Quick, accurate, and affordable determination for both production control and research
Calibration, analysis, evaluation, and diagnostic functions accessible via user-friendly brand software
GDS GDS 500A and 850A Atomic Emission Spectrometers
Spectral range from 120 to 800 nm
Continuous profile of concentration/thickness
Large, dynamic range with concentrations from ppm to 100% by weight
Short analysis time (minutes)
双直流风扇保证持续冷却,不受电压波动的影响。上海分析仪多少钱
可选具有压力补偿和温度控制性能的标气检测气路。上海分析仪多少钱
氧氮氢分析仪的原理:分析样品在惰性气流存在下于石墨坩埚中加热熔融,其中脉冲炉温度可自由设定,并通过一个非接触式的光学温度传感器进行实时监控,用于实现样品的完全分解,反应所生成的CO H2和N2被带入到具有高稳定性和灵敏度的检测系统进行检测。对于CO的检测采用的是非色散性红外检测器,对于N2和H2的检测则采用热导检测器。
氧氮氢分析仪的特点:快速准确分析,自动化操作;精密气体校准;CO红外检测器,高分辨率和重现性的N、H热导池检测器;同一台仪器实现熔融提取和热提取;热提取分析时间可调;可自由选择温度*高达2500 °C;光学温度计温度测定和控制;所有检测器自动调零/自动水平控制(ALC);数据评估的自动优化选择范围;炉自动清洁和坩埚自动进样(可选);外设电脑进行操作和控制;样品信息保存; 所有样品数据可追踪查询;通过FTP或本地局域网进行数据传输; ON,H分析轻松切换。
上海分析仪多少钱
氧氮氢分析仪的常见故障及解决方法仪器启动时显示。没有水流。系统分析电流切断,分析停止。这是水流探测器...
【详情】736Series:Oxygen/NitrogenbyInertGasFusionThe736fam
【详情】美国LECO力可氧氮氢分析仪ONH836氧氮氢联测仪系列软件部分1、用户友好界面的Cornersto...
【详情】Procedure–Powder/ChipSamplesInstrumentcalibration/...
【详情】LECO—YoursourcefortotalanalyticalsolutionsCSCS844a...
【详情】InstrumentHighlightsandFeaturesFeaturesandBenefits
【详情】仪器的亮点和优势:特点和优势·炉头区域LED照明系统·炉头快速拆装的粉尘过滤装置·装有自动旁路阀的可...
【详情】Procedure–Powder/ChipSamplesDeterminetheinstrument...
【详情】氧氮氢分析仪的常见故障及解决方法供电正常、通讯正常,点击确认键后分析仪不工作。这是没有水流,炉子温度...