User-FriendlyBrandSoftwareCornerstoneLECOsexclusivebrandsoftwareenablestheusertohavecompleteaccesstoanalysisCornerstonecontrol,methodsettings,diagnostics,reporting,andmoreinahighlyorganizedandimmersiveenvironment.Designedthroughacollaborationofcustomerfeedbackandinnovativeengineering,Cornerstoneallowstheusertoconductalloftheirday-to-dayoperationswithinasingleAnalysisscreendesignedforspeedandease-of-use.Ourinnovativegroupingofsampledataintosetsandreplicatessimplifiesthedataoutputandautomaticallycalculatesrelevantstatistics,alleviatingtheneedforadditionaldataprocessing.OHN836系列仪器采用惰性熔融法。北京分析仪厂家直销
LECO—YoursourcefortotalanalyticalsolutionsCSCS844and744Series:Carbon/SulfurbyCombustionCarbonandsulfurdeterminationbycombustioninfrareddetectionQuick,accurate,andaffordabledeterminationforbothproductioncontrolandresearchCalibration,analysis,evaluation,anddiagnosticfunctionsaccessibleviauser-friendlybrandsoftwareGDSGDS500Aand850AAtomicEmissionSpectrometersSpectralrangefrom120to800nmContinuousprofileofconcentration/thicknessLarge,dynamicrangewithconcentrationsfromppmto100%byweightShortanalysistime(minutes)江苏LECO分析仪咨询报价强力内循环水冷装置。
InstrumentHighlightsandFeaturesFeaturesandBenefitsLEDlightringilluminatesthefurnaceareaChoiceofeitherargonorheliumcarriergasNovelelectrodedesignincreasesheattransferefficiencyforincreasedstabilityNon-touchinterfacesystemsarealsoavailableUser-friendlybrandsoftwareHigh-PerformanceDetectorDesignThermostaticconstructionprovidesincreasedprotectionfromambienttemperaturefluctuationsOptimizedemittercontrolanddetectioncircuitryimprovestheIRcelllifetimeandlong-termstability,resultinginsuperioraccuracyandprecisionInfrareddetectionforthedeterminationofoxygen,thermoconductivitydetectionforthedeterminationofnitrogen
氧氮氢分析仪是快速、准确分析氧、氮、氢元素的、高性能仪器,整机采用模块化、一体化设计,即主机由可靠的脉冲电极炉、高灵敏高精度的检测系统、布局合理和气密性好的气路系统、可靠耐用的电源系统、稳定的电路系统、高校节能的水循环散热系统等六个**的硬件模块单元组成。氧氮氢分析仪的测量原理:测量范围非常***。分析样品时,样品被称重后放到样品端口中,然后用载气进行冲洗,防止大气(含氧气和氮气)进入到炉子系统中。石墨坩埚在脉冲炉中脱气,以尽量减少自带的污染。经过稳定阶段后样品落入坩埚中并熔融。样品中的氧与石墨坩埚中的碳反应生成一氧化碳。氮和氢以单质的形式释放。载气和样品气体通过粉尘过滤网后再进入到氧化铜催化炉中,将一氧化碳氧化成二氧化碳。二氧化碳进入到红外池中用于测定氧含量,被测后的气体导入化学试剂管,这时二氧化碳和水被化学试剂除去,氮元素通过热导检测池含量被测定。测量氢时,载气换为氮气,样品气体通过舒茨试剂而不是氧化铜催化剂。测氧和氮时也可采用更廉价的氩气作为载气。高性能的红外检测器配置***恒温绝热技术,消除了外界环境温度的干扰。
Procedure–Powder/ChipSamplesInstrumentcalibration/driftcorrection.Addapproximately0.05gof***GraphitePowdertoa***GraphiteCrucible.Firmlyplacethecrucibleonthelowerelectrodetiporappropriateautoloaderposition.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically.Repeatsteps3bthrough3iaminimumofthreetimesforeachcalibration/driftstandardused.装有自动旁路阀的可快速拆装氧水捕集装置。山东元素分析仪厂家供应
国际**的非色散红外及热导检测器 ,无移动部件,不需要手动调整。北京分析仪厂家直销
SamplePreparationTypically,titaniumandzirconiumsamplesarechemicallyetchedtoremovesurfacecontaminationwhenoxygenandnitrogenaredetermined.However,etchingcanintroducehydrogenintothesample.ASTMmethodE1409"DeterminationofOxygenandNitrogeninTitaniumandTitaniumAlloysbytheInertGasFusionTechnique",asupdatedin1996,permitseitheretchingorabrading(filing)ofthetestspecimen.ASTME1447"DeterminationofHydrogeninTitaniumandTitaniumAlloysbytheInertGasFusionThermalConductivity/InfraredDetectionMethod"permitssurfacepreparationbyabrading(ifnecessarytoremovecontamination).DifferencesinsamplepreparationpresentsomewhatofadilemmaregardingsimultaneousdeterminationofO,N,andHintitanium.However,abradingsampleswithafiletoremovesurfacecontaminationwillyieldaccurateO,N,andHresults.TheONH836utilizesahigh-powerelectrodefurnacetoquicklyandefficientlyreleasethetargetgasesfromwithinthesample,whichallowsforaveryrapidsimultaneousdeterminationofoxygen,nitrogen,andhydrogen.北京分析仪厂家直销
氧氮氢分析仪的常见故障及解决方法仪器启动时显示。没有水流。系统分析电流切断,分析停止。这是水流探测器...
【详情】736Series:Oxygen/NitrogenbyInertGasFusionThe736fam
【详情】美国LECO力可氧氮氢分析仪ONH836氧氮氢联测仪系列软件部分1、用户友好界面的Cornersto...
【详情】Procedure–Powder/ChipSamplesInstrumentcalibration/...
【详情】LECO—YoursourcefortotalanalyticalsolutionsCSCS844a...
【详情】InstrumentHighlightsandFeaturesFeaturesandBenefits
【详情】仪器的亮点和优势:特点和优势·炉头区域LED照明系统·炉头快速拆装的粉尘过滤装置·装有自动旁路阀的可...
【详情】Procedure–Powder/ChipSamplesDeterminetheinstrument...
【详情】氧氮氢分析仪的常见故障及解决方法供电正常、通讯正常,点击确认键后分析仪不工作。这是没有水流,炉子温度...
【详情】